PULSTECPulstec Industrial Co.,Ltd.Japanese
Contact Us
Calendar
Site Map
HomeProductR&DSupportIR InformationAbout Pulstec
Home > Product > Optical Application > Optical Application FAQs
Product
X-ray Application
Optical Application
Optical Disc
Exhibition Information
Office & Agency
Main offices
Affiliated companies Agencies

  
Optical Application FAQs

Nano Technology 3D Measurement Aberration Measurement
Nano Technology
[ NEO-500 ]
QIs it possible to fabricate user's sample brought to Pulstec?
QWhat kind of the shape of substrate is supported?
QHow fast is the processing speed?
QWhat kind of application is the system used for?

3D Measurement
[ 3D Scanner ]
QWhat are the features of 3D scanner TDS series?
QHow wide is the scanning area?
QWhat kind of data can be scanned?
QIs there any object the data cannot be measured?
QIs data accuracy checked?
QWhat is the speed of scanning?
QIs it possible to obtain color data with 3D data?

Aberration Measurement
[ PWS-1000 Wavefront Sensor ]
QWhat is the method and feature?
QWhat is the system structure?
QHow do you calibrate?
QWhat is your recommended PC specification?
QWhat is your recommended extended IEEE 1394 interface?



QIs it possible to fabricate user's sample brought to Pulstec?[ NEO-500 ]
AThe system can draw nano-dot on photo-resist or thermal-resist applied surface of the substrate such as Si, glass and polycarbonate. NEO-500 uses the laser lithography technology.
 
QWhat kind of the shape of substrate is supported?[ NEO-500 ]
A Maximum size is up to φ12cm optical disc shape. The system uses air absorption rotational stage to hold the substrate and draw nano-dot in spiral.
 
QHow fast is the processing speed?[ NEO-500 ]
AThe spindle can rotate at 10,000 rpm. For example, it takes 10 minutes to draw nano-dot pattern, with 1.5um interval which is similar to photonic crystal structure, on the 2 inches wafer.
 
QWhat kind of application is the system used for?[ NEO-500 ]
AOptical device such as anti-reflective structure and wavelength plate, next-generation hard disc, next-generation memory, and element sensing chip.
 
QWhat are the features of TDS?[ 3D Scanner ]
ATDS series is implemented with FPC (field power control) function.
Without spraying, TDS series can obtain the data from the black colored and burnish objects which are generally difficult to be measured with laser.
Data can be obtained even if there are many colors in the measurement area.
Because it can be used outside, it is used for archaeological dig.
 
QHow wide is the the scanning area?[ 3D Scanner ]
AField of view and resolution level depend on a scanner type.
We have several types of scanners designed for various application purpose.
Our product lineup starts with the narrow range type (for the cm order area), up to the wide range type (covers the angle of 360 degree).
Our product lineup covers from high resolution measurement with close-up focus to wide range measurement at distant view.
 
QWhat kind of data can be scanned?[ 3D Scanner ]
AMany kinds of materials can be scanned. For example, automotive parts (such as sheet metal product, metal foundry), plastic, rubber, papers, human skins, plants, dirt, rocks, wood, concrete, glass, potteries, iron, etc.
High resolution model can obtain the data from fingerprint, wrinkle on the skin, concavity and convexity of words on the coins, etc.
 
QIs there any object the data cannot be measured?[ 3D Scanner ]
AHigh reflectivity objects such as mirrors cannot be measured because TDS analyzes the scattered beam.
It is also difficult to scan the transparent materials such as glass, water surface, etc.
 
QIs data accuracy checked?[ 3D Scanner ]
AWe inspect the accuracy of all scanners before the shipment.
Each scanner is inspected by the test equipment certified by the Japan Quality Assurance Organization (JQA). e.g.) variation of weighted center and flat surface tolerance.
 
QWhat is the speed of scanning? [ 3D Scanner ]
A•TDS series
Area scan typically takes from 2.4 to 15.4sec, while line scan takes from 0.024 to 0.055sec. Multiple scanning mode is available from ''high speed scanning'' to ''high density scanning''.
•FCAN
It takes only about 1second to obtain high-accuracy 3D data.
 
QIs it possible to obtain color data with 3D data?[ 3D Scanner ]
AFSCAN can obtain 3D data and color data at the same time.
However, it is impossible to do the same thing with TDS series, because TDS uses laser scanning method.
So, it is necessary to obtain the color data independently and apply to the 3D data by image processing.
 
QWhat is the method and feature?[ Wavefront Sensor ]
AShack-Hartmann method is used for PWS-1000. The features of this method are as following; compact in size, real time measurement, high dynamic range, and strong to vibration. It does not have any influence from the interferometer and is able to measure with more than one wavelength.
 
 
QWhat is the system structure? [ Wavefront Sensor ]
APWS-1000 is consisted of wavefront sensor, measurement software, IEEE 1394 cable for connection. If you have PC with IEEE 1394 interface (6 pins), you can start measuring right away. You can also purchase PC from us.
 
 
QHow do you calibrate? [ Wavefront Sensor ]
AWe recommend our LD Reference Diode Laser Source (Wavelength:405nm/655nm/780nm) which is proven calibration laser source for interferometer.
We will attach a calibration data in your desired wavelength on sending. Also, on-site calibration service is available for regular check.
 
 
QWhat is your recommended PC specification? [ Wavefront Sensor ]
A

If specification below is fulfilled, it does not matter if you use desk-top or lap-top PC.
If there is no IEEE1394 interface, you can use external expansion board as well.

OSWindows XP Professional 32bit English Edition*1
Windows Vista Business 32bit English Edition*1*2
CPUIntel Pentium4 Processor 2.4GHz(HT) and above. *3
Expanded MemoryIf Windows XP Professional 32bit English Edition, 1GB and above.
If Windows Vista Business 32bit English Edition, 2GB and above.
Capacity of empty HDD100MB and above.
Optical DriveSupporting CD-ROM (Necessary for installation)
Graphic boardSupporting DirectX9.0c and above.
MonitorSXGA(1280*1024) and above.
Unused IEEE1394 PortSupporting IEEE1394a (400Mbps) 6 pin 1 place*4*5
Unused USB PortSupporting USB2.0 1 place*6
*1DirectX End-User Runtime should be installed in advance.
*2PC that recognize Pulstec Wavefront Sensor in Windows Vista can only be used.
*3Cannot execute software on Intel Pentium 3 and below.
(More than Intel Pentium 4 or Intel Pentium M)
*4It would be used to connect Pulstec Wavefront Sensor.
*5When used with laptops, Pulstec Wavefront Sensor may not operate due to power shortage.
*6It would be used to connect guard key.
 
 
QWhat is your recommended extended IEEE 1394 interface? [ Wavefront Sensor ]
A

We have confirmed operation of extended IEEE 1394 interface as written below.

•For lap-top PC (PC card Card Bus, Slot Insert Type II)
<Manufacturer> RATOC Systems, Inc. Model: REX-CFW3H
<Special AC Adapter> Model: RSO-AC01
Notice! Since power is supplied by bus power, please be sure to use with the special adapter mentioned above.

•For desk-top PC (PCI Bus)
<Manufacturer> I-O DATA Model: 1394PCI3

 

Contact Us